Resumen
En Colombia, alrededor de 1’486.213 personas tienen algún tipo de discapacidad, de las cuales 19% tiene dificultad de llevar, mover y/o utilizar objetos con las manos. Dentro de este grupo se encuentran las amputaciones de mano, donde sus principales causas son traumatismos, causas congénitas y vasculares. Las prótesis nacen de la necesidad de suplir la función del miembro faltante y su principal desarrollo ha sido con materiales rígidos. Sin embargo, factores como el peso, costo, aspecto físico, entre otros, hacen que los usuarios no estén completamente satisfechos con el dispositivo. Las prótesis basadas en soft-robotics son aquellas que para su estructura usan materiales con módulos de elasticidad similares a los del cuerpo humano o aquellas que tienen articulaciones elásticas y su mecanismo de actuación es por cables. Este proyecto tiene como objetivo evaluar mecánica y funcionalmente una prótesis de mano basada en soft-robotics, la prótesis se desarrolló bajo el marco del proyecto PrExHand y su objetivo principal es que además de ser funcional, sea de bajo costo. La prótesis PrExHand es un dispositivo electroneumático. La flexión y extensión de los dedos se hace con unos tendones que van a un motor y la abducción y aducción de los dedos se hace con actuadores de silicona controlados por aire. Dentro del proyecto se han propuesto dos diseños, que se evaluaran en el marco de este trabajo de grado. El diseño A (PrExHand A), une los tendones que actúan los dedos al motor por medio de un elemento inelástico y algunas partes de los dedos están cubiertas con silicona. El diseño B (PrExHand B), une los tendones al motor por medio de un mecanismo deslizable ubicado en la palma de la mano protésica y los dedos tienen un recubrimiento completo con silicona. El objetivo dentro de esta tesis es determinar los pros y contras de los diseños y proponer la versión final que será evaluada con pacientes. Para esto se utilizan pruebas mecánicas y funcionales que permitieron caracterizar las prótesis. La revisión de literatura permitió conocer cuáles son las pruebas mecánicas y funcionales utilizadas generalmente en prótesis. Del estado del arte, se definieron 3 pruebas mecánicas: fuerza de agarre, energía y fuerza de tracción. También se encontró el protocolo de evaluación de manos antropomórficas (AHAP, por sus siglas en inglés Anthropomorphic Hand Assessment Protocol), para aplicar a los dos diseños planteados para la prótesis PrExHand. Los resultados de las pruebas mecánicas mostraron que el diseño A tiene una fuerza de agarre máxima de 22,07 ± 2,03 N, para cerrarse requiere una energía de 0,76 ± 2,03 J, disipa una energía de 0,21 ± 0,17 J y soporta una fuerza de tracción de 173,31 ± 5,66 N. Por otro lado, el diseño B tiene una fuerza de agarre máxima de 33,68 ± 1,34 N, para cerrarse requiere una energía de 1,28 ± 0,13 J, disipa una energía de 0,96 ± 0,12 J y soporta una fuerza de tracción de 78,48 ± 0 N. En la pruebas funcional, además de probar los dos diseños de la prótesis PrExHand, se probó la prótesis robótica de la empresa Prótesis Avanzadas. Esta prueba mostró como resultado que la Prótesis comercial tenía un puntaje mayor, es decir que su funcionalidad es similar a la mano en un 79,31 %, seguida por PrExHand A en un 73,33% y PrExHand B en un 69,17 %. En conclusión, mecánicamente PrExHand A tuvo resultados más cercanos a lo esperado en energía y en la fuerza de tracción que soporta. La diferencia entre los resultados relacionados con energía y fuerza de tracción se encuentran relacionados a dos características de PrExHand B. Por un lado, los dedos tienen un recubrimiento completo en silicona y por el otro, el mecanismo deslizable, los cuales causaron que el motor tuviera que generar más fuerza en los tendones para cerrar la prótesis. Por otro lado, la fuerza de agarre de PrExHand B tuvo un resultado mayor respecto al diseño A. Esto consecuencia de que las siliconas permitieron que la prótesis pudiera agarrar de forma más idónea el dinamómetro y tener resultados más altos. Finalmente, aunque funcionalmente la prótesis comercial tuvo mayores resultados generales, respecto a los dos diseños de la prótesis PrExHand, en algunos tipos de agarres se vio que estas últimas tenían puntajes más altos. Esto abre la posibilidad de aplicar en la prótesis comercial de Prótesis Avanzadas algunos de los conceptos utilizados en los agarres donde los puntajes para las prótesis PrExHand fueron mayores.
Abstract
In Colombia, around 1'486,213 people have some type of disability, 19% of them have difficulty carrying, moving, and/or using objects with their hands. Within this group are hand amputations, where the main causes are traumatisms, congenital and vascular causes. Prostheses arise from the need to replace the function of the missing limb and their main development has been with rigid materials. However, factors such as weight, cost, physical appearance, among others, make users not completely satisfied with the device. Prostheses based on soft-robotics are those that for their structure use materials with elasticity modules similar to the human body or those that have elastic joints and their actuation mechanism is by cables. This project aims to mechanically and functionally evaluate a hand prosthesis based on soft-robotics. The prosthesis was developed under the framework of the PrExHand project, and its main objective is that in addition to being functional, it is low cost. The PrExHand prosthesis is an electro-pneumatic device. The flexion and extension of the fingers are done with tendons that go to a motor and the abduction and adduction of the fingers are done with air-controlled silicone actuators. Two designs have been proposed within the project, which will be evaluated within the framework of this degree work. Design A (PrExHand A) links the tendons that actuate the fingers to the motor using an inelastic element and some parts of the fingers are covered with silicone. Design B (PrExHand B) links the tendons to the motor using a sliding mechanism located in the palm of the prosthetic hand, and the fingers are completely covered with silicone. The objective of this thesis is to determine the pros and cons of the designs and propose the final version that will be evaluated with patients. For this purpose, mechanical and functional tests are used to characterize the prostheses. The literature review provided information on the mechanical and functional tests generally used in prostheses. From the state of the art, 3 mechanical tests were defined: grip force, energy, and tensile force. The Anthropomorphic Hand Assessment Protocol (AHAP) was also found, to be applied to the two designs proposed for the PrExHand prosthesis. The results of the mechanical tests showed that design A has a maximum grip force of 22.07 ± 2.03 N, requires the energy of 0.76 ± 2.03 J to close, dissipates the energy of 0.21 ± 0.17 J, and withstands a tensile force of 173.31 ± 5.66 N. On the other hand, design B has a maximum grip force of 33.68 ± 1.34 N, to close requires the energy of 1.28 ± 0.13 J, dissipates the energy of 0.96 ± 0.12 J, and withstands a tensile force of 78.48 ± 0 N. In functional testing, in addition to testing the two designs of the PrExHand prosthesis, the robotic prosthesis from Prótesis Avanzadas was tested. This test showed as a result that the commercial prosthesis had a higher score what it means that its functionality is similar to the hand in 79.31%, followed by PrExHand A with 73.33% and PrExHand B with 69.17%. In conclusion, mechanically PrExHand A had results closer to the expected in energy and in the tensile force that supports. The difference between the results related to energy and traction force is related to two characteristics of PrExHand B. On the one hand, the fingers have a full silicone coating and on the other hand, the sliding mechanism caused the motor to have to generate more force on the tendons to close the prosthesis. The grip force of PrExHand B performed better than design A. This was a consequence of the fact that the silicones allowed the motor to generate more force on the tendons to close the prosthesis. This was a consequence of the silicones allowing the prosthesis to grip the dynamometer better and have higher results. Finally, although functionally the commercial prosthesis performed better overall than the two PrExHand prosthesis designs, in some types of grips it was seen that the latter had higher scores. This opens the possibility of applying some of the concepts used in the grips where the scores for the PrExHand prostheses were higher than the commercial prosthesis of Advanced Prosthetics.
Palabras clave
Evaluación funcional de protesis robotica de mano , Diagnostico de usabilidad del protesis electroneumática de mano de Soft-Robotics , Tecnología medica , Diseño del protocolo de evaluación de funcionalidad mecánica de prótesis robótica de mano , Uso de prótesis robótica para la rehabilitación de pacientes amputados
Keywords
Functional evaluation of robotic hand prosthesis , Soft-Robotics Handheld Electropneumatic Prosthesis Usability Diagnosis , Medical technology , Design of the protocol for the evaluation of mechanical functionality of robotic hand prostheses , Use of robotic prostheses for the rehabilitation of amputees
Buscar en: