Ítem
Acceso Abierto

Predictive validity of the body adiposity index in overweight and obese adults using dual-energy X-ray absorptiometry

dc.contributor.gruplacCentro de Estudios en Medición de la Actividad Física (CEMA)spa
dc.creatorRamírez-Vélez, Robinson
dc.creatorCorrea Bautista, Jorge Enrique
dc.creatorGonzález-Ruíz, Katherine
dc.creatorTriana Reina, Héctor Reynaldo
dc.creatorVivas, Andrés
dc.creatorGarcía-Hermoso, Antonio
dc.creator.googleRamírez-Vélez, Robinson
dc.creator.googleCorrea Bautista, Jorge Enrique
dc.creator.googleGonzález-Ruíz, Katherine
dc.creator.googleTriana Reina, Héctor Reynaldo
dc.creator.googleGarcía-Hermoso, Antonio
dc.creator.googleVivas, Andrés
dc.date.accessioned2018-03-05T12:25:42Z
dc.date.available2018-03-05T12:25:42Z
dc.date.created2016-11
dc.date.issued2016
dc.description.abstractThe body adiposity index (BAI) is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF%) in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA) as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old). DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001). The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0), indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957). In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied.eng
dc.format.mimetypeapplication/pdf
dc.identifier.doihttps://doi.org/10.3390/nu8120737
dc.identifier.issn2072-6643
dc.identifier.urihttp://repository.urosario.edu.co/handle/10336/15195
dc.language.isoeng
dc.relation.citationEndPage11
dc.relation.citationStartPage1
dc.relation.citationTitleNutrients
dc.relation.ispartofNutrients, ISSN 2072-6643 (2016); pp. 1-11spa
dc.relation.urihttp://www.mdpi.com/2072-6643/8/12/737
dc.rights.accesRightsinfo:eu-repo/semantics/openAccess
dc.rights.accesoAbierto (Texto Completo)spa
dc.rights.cchttp://www.mdpi.com/about/openaccessspa
dc.rights.urihttp://www.sherpa.ac.uk/romeo/issn/272-6643/es/
dc.source.instnameinstname:Universidad del Rosario
dc.source.reponamereponame:Repositorio Institucional EdocUR
dc.subjectBody Compositionspa
dc.subjectValidityspa
dc.subjectPredictionspa
dc.subjectObesityspa
dc.subjectAdultsspa
dc.subject.ddcFisiología humana
dc.subject.decsObesidadspa
dc.subject.decsAdiposidadspa
dc.subject.decsDislipidemiasspa
dc.subject.decsSíndrome Metabólicospa
dc.titlePredictive validity of the body adiposity index in overweight and obese adults using dual-energy X-ray absorptiometryspa
dc.typearticleeng
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion
dc.type.spaArtículospa
Archivos
Bloque original
Mostrando1 - 1 de 1
Cargando...
Miniatura
Nombre:
PDF9.pdf
Tamaño:
400.95 KB
Formato:
Adobe Portable Document Format
Descripción:
Colecciones