Ítem
Acceso Abierto

Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obeses Colombian adults

dc.creatorRamírez-Vélez, Robinson
dc.creatorTordecilla Sanders, María Alejandra
dc.creatorCorrea Bautista, Jorge Enrique
dc.creatorGonzález Ruíz, Katherine
dc.creatorGonzález Jiménez, Emilio
dc.creatorTriana-Reina, Hector Reynaldo
dc.creatorGarcía-Hermoso, Antonio
dc.creatorSchmidt-RioValle, Jacqueline
dc.creator.googleRamírez-Vélez, Robinsonspa
dc.creator.googleTordecilla-Sanders, Alejandra
dc.creator.googleCorrea-Bautista, Jorge Enrique
dc.creator.googleGonzález Ruíz, Katherine
dc.creator.googleGonzález Jiménez, Emilio
dc.creator.googleTriana-Reina, Hector Reynaldo
dc.creator.googleGarcía-Hermoso, Antonio
dc.creator.googleSchmidt-RioValle, Jacqueline
dc.date.accessioned2019-02-15T20:01:13Z
dc.date.available2019-02-15T20:01:13Z
dc.date.created2018
dc.date.issued2018
dc.description.abstractObjectives: To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Methods: Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland–Altman difference plots. Results: Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P =.001). The paired t-test showed a significant mean difference between these methods for obese men BF% of −0.6 [(SD 1.95; 95% CI = −4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was −0.6 [(SD 2.2; 95% CI = −5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Conclusions: Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.eng
dc.format.mimetypeapplication/pdf
dc.identifier.doi10.1002/ajhb.23071
dc.identifier.issn1042-0533
dc.identifier.urihttp://repository.urosario.edu.co/handle/10336/19090
dc.language.isoengspa
dc.relation.citationTitleAmerican Journal of Human Biology
dc.relation.citationVolumeVol. 30
dc.relation.ispartofAmerican Journal of Human Biology, ISSN:1042-0533, Vol. 30 (2018)spa
dc.relation.urihttps://onlinelibrary.wiley.com/doi/full/10.1002/ajhb.23071spa
dc.rights.accesRightsinfo:eu-repo/semantics/openAccess
dc.rights.accesoAbierto (Texto Completo)spa
dc.source.bibliographicCitationAslam, M., Eckhauser, A.W., Dorminy, C.A., Dossett, C.M., Choi, L., Buchowski, M.S., Assessing body fat changes during moderate weight loss with anthropometry and bioelectrical impedance (2009) Obesity Research & Clinical Practice, 3, pp. 209-219spa
dc.source.instnameinstname:Universidad del Rosario
dc.source.reponamereponame:Repositorio Institucional EdocUR
dc.subjectMulti‐Frequency Bioelectricalspa
dc.subjectDual‐Energy X‐Ray Absorptiometryspa
dc.subject.ddcBiologíaspa
dc.subject.lembComposición del cuerpo humanospa
dc.subject.lembPeso corporalspa
dc.subject.lembConvertidos de corriente eléctricaspa
dc.titleValidation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obeses Colombian adultsspa
dc.typearticleeng
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion
dc.type.spaArtículospa
Archivos
Bloque original
Mostrando1 - 1 de 1
Cargando...
Miniatura
Nombre:
114.pdf
Tamaño:
605.05 KB
Formato:
Adobe Portable Document Format
Descripción:
Colecciones