Ítem
Acceso Abierto

A retrospective study on the relationship between altered native acetabular angle and vertical implant malpositioning

dc.creatorRojas J.spa
dc.creatorBautista M.spa
dc.creatorBonilla G.spa
dc.creatorAmado O.spa
dc.creatorHuerfano E.spa
dc.creatorMonsalvo D.spa
dc.creatorLlinás A.spa
dc.creatorNavas J.spa
dc.date.accessioned2020-05-25T23:55:39Z
dc.date.available2020-05-25T23:55:39Z
dc.date.created2018spa
dc.description.abstractPurpose: Acetabular cup positioning in extreme angles of vertical position affects both stability and long-term survivorship of total hip arthroplasty. The purpose of this study is to determine whether native Sharp’s angle is associated with an increased abduction angle of the acetabular component. Methods: Consecutive patients who underwent primary total hip replacement between February 2012 and August 2015 were included. Vertical positioning of acetabular implant in the antero-posterior post-operative radiographs were measured. The proportion of implants positioned outside the safe zone (40° ± 10°) was calculated and through a multivariate analysis, Sharp’s angle and other factors possibly associated with cup malpositioning were evaluated. Results: Five hundred twenty-eight hip arthroplasties were analyzed. Prevalence of cup malpositioning was 7.6% and 25 patients had an altered native acetabular angle. An altered pre-operative Sharp’s angle was associated with a higher risk of vertical malpositioning of the acetabular component (OR 2.51 IC 95%: 1.17–5.39) (p = 0.02). Body mass index, surgeon’s volume, size of the implant, gender, pre-operative diagnose and age, were not associated with the position of the cup. Conclusions: The alteration of the Sharp’s angle as an indicator of hip dysplasia in native hips increases the odds of acetabular cup malpositioning. Other factors explored did not correlate with the position of the acetabular prosthesis. Systematic assessment of Sharp’s angle should be included in the pre-operative planning of primary hip arthroplasty. © 2017, SICOT aisbl.eng
dc.format.mimetypeapplication/pdf
dc.identifier.doihttps://doi.org/10.1007/s00264-017-3584-1
dc.identifier.issn14325195
dc.identifier.issn03412695
dc.identifier.urihttps://repository.urosario.edu.co/handle/10336/22165
dc.language.isoengspa
dc.publisherSpringer Verlagspa
dc.relation.citationEndPage775
dc.relation.citationIssueNo. 4
dc.relation.citationStartPage769
dc.relation.citationTitleInternational Orthopaedics
dc.relation.citationVolumeVol. 42
dc.relation.ispartofInternational Orthopaedics, ISSN:14325195, 03412695, Vol.42, No.4 (2018); pp. 769-775spa
dc.relation.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85026913039&doi=10.1007%2fs00264-017-3584-1&partnerID=40&md5=13f063326eca099f03a2396fdd347e24spa
dc.rights.accesRightsinfo:eu-repo/semantics/openAccess
dc.rights.accesoAbierto (Texto Completo)spa
dc.source.instnameinstname:Universidad del Rosariospa
dc.source.reponamereponame:Repositorio Institucional EdocURspa
dc.subject.keywordAbductionspa
dc.subject.keywordreplacementeng
dc.subject.keywordhipeng
dc.subject.keywordAdultspa
dc.subject.keywordAgedspa
dc.subject.keywordArticlespa
dc.subject.keywordFemalespa
dc.subject.keywordHumanspa
dc.subject.keywordMajor clinical studyspa
dc.subject.keywordMalespa
dc.subject.keywordMeasurementspa
dc.subject.keywordMedical device complicationspa
dc.subject.keywordMultivariate analysisspa
dc.subject.keywordMusculoskeletal system parametersspa
dc.subject.keywordOsteoarthritisspa
dc.subject.keywordPrevalencespa
dc.subject.keywordPriority journalspa
dc.subject.keywordRetrospective studyspa
dc.subject.keywordSurgical techniquespa
dc.subject.keywordVertical implant malpositioningspa
dc.subject.keywordAcetabulumspa
dc.subject.keywordAdverse device effectspa
dc.subject.keywordComplicationspa
dc.subject.keywordCongenital hip dislocationspa
dc.subject.keywordDiagnostic imagingspa
dc.subject.keywordHipspa
dc.subject.keywordHip prosthesisspa
dc.subject.keywordHip replacementspa
dc.subject.keywordMiddle agedspa
dc.subject.keywordProsthesis complicationspa
dc.subject.keywordRegisterspa
dc.subject.keywordRisk factorspa
dc.subject.keywordVery elderlyspa
dc.subject.keywordYoung adultspa
dc.subject.keywordAcetabulumspa
dc.subject.keywordAdolescentspa
dc.subject.keywordAdultspa
dc.subject.keywordAgedspa
dc.subject.keywordAged, 80 and overspa
dc.subject.keywordArthroplastyeng
dc.subject.keywordFemalespa
dc.subject.keywordHip dislocationeng
dc.subject.keywordHip jointspa
dc.subject.keywordHip prosthesisspa
dc.subject.keywordHumansspa
dc.subject.keywordMalespa
dc.subject.keywordMiddle agedspa
dc.subject.keywordProsthesis failurespa
dc.subject.keywordRegistriesspa
dc.subject.keywordRetrospective studiesspa
dc.subject.keywordRisk factorsspa
dc.subject.keywordYoung adultspa
dc.subject.keywordAcetabular cup positioningspa
dc.subject.keywordAcetabulumspa
dc.subject.keywordArtrhoplastyeng
dc.subject.keywordHip prosthesis implantationspa
dc.titleA retrospective study on the relationship between altered native acetabular angle and vertical implant malpositioningspa
dc.typearticleeng
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion
dc.type.spaArtículospa
Archivos
Bloque original
Mostrando1 - 1 de 1
Cargando...
Miniatura
Nombre:
Rojas2018_Article_ARetrospectiveStudyOnTheRelati.pdf
Tamaño:
439.22 KB
Formato:
Adobe Portable Document Format
Descripción:
Colecciones