Ítem
Acceso Abierto

Rompiendo un mito en el control de la hemoglobina/hematocrito postransfusión

dc.creatorPardo Oviedo, Juan Mauricio
dc.creatorPanqueva Martínez, Urielspa
dc.creatorEspinosa Aranzales, Ángela Fernanda
dc.date.accessioned2020-06-11T13:22:04Z
dc.date.available2020-06-11T13:22:04Z
dc.date.created2010spa
dc.descriptionHabitualmente se ha solicitado la hemoglobina/hematocrito después de las seis horas como parámetro para evaluar el resultado terapéutico de la transfusión sin que exista evidencia clara para hacerlo. Objetivo: determinar la concordancia de los niveles de hemoglobina/hematocrito en los primeros 15 minutos de terminada la transfusión comparado con la toma de éstos a las seis horas en pacientes con anemia crónica sin sangrado activo, hemólisis o hiperesplenismo. Materiales y métodos: se realizó un estudio, observacional, analítico de concordancia que analizó la consistencia entre dos mediciones de hemoglobina/hematocrito tomada dentro de los primeros 15 minutos de terminada la transfusión y seis horas después en 41 pacientes con anemia de origen médico, sin sangrado activo. Resultados: se encontró concordancia significativa alta entre la hemoglobina a los 15 minutos y seis horas después de la transfusión (p<0.0001) con un coeficiente de correlación intraclase de 0.8793 (IC 95: 0.7817, 0.9349); igualmente se encontró concordancia significativa alta entre el hematocrito a los 15 minutos y a las seis horas después de la transfusión (p<0.0001) con un coeficiente de correlación intraclase de 0.8456 (IC 95%: 0.7301, 0.9144). Conclusiones y discusión: aunque es una práctica habitual la toma de hemoglobina-hematocrito seis horas después de la transfusión, sin evidencia en la literatura que lo respalde, este estudio encontró que existe concordancia alta, significativa entre la toma de la hemoglobina/hematocrito 15 minutos y seis horas después de terminada la transfusión en pacientes con anemia de origen médico, lo que permite una toma inmediata, ahorrando tiempo en la decisión clínica (Acta Med Colomb 2010; 35: 2-7).spa
dc.description.abstractMeasurement of hemoglobin/hematocrit is usually carried out 6 hours after transfusion, as a parameter allowing the assessment of therapeutic result. However, there is no clear evidence to support this practice. Objective: to determine the concordance of the levels of hemoglobin/hematocrit 15 minutes after termination of transfusion, with regard to those measured 6 hours after the procedure, in patients with chronic anemia and without active bleeding, hemolysis, or hypersplenism. Materials and methods: an observational, analytic, concordance study was carried out in order to analyze the concordance between 2 measurements of hemoglobin/hematocrit: 15 minutes after transfusion and 6 hours after transfusion. This was done in 41 diagnosed with anemia of medical origin, without active bleeding. Results: a highly significant concordance was found between hemoglobin at 15 minutes and 6 hours after transfusion (p<0.0001), with an intraclass correlation coefficient of 0.8793 (IC 95: 0.7817, 0.9349); highly significant concordance was also found between hematocrit at 15 minutes and 6 hours after transfusion (p<0.0001), with an intraclass correlation coefficient of 0.8456 (IC 95%: 0.7301, 0.9144). Conclusions and discussion: although it is common practice to determine hemoglobin/hematocrit 6 hours after transfusion (without supporting evidence reported in the literature), this study found a high, significant correlation between measurements carried out at 15 minutes and 6 hours after transfusion in patients with anemia of medical origin. Immediate measurement saves time in clinical decisions (Acta Med Colombiana 2010; 35: 2-7).spa
dc.format.mimetypeapplication/pdf
dc.identifier.issn0120-2448
dc.identifier.urihttps://repository.urosario.edu.co/handle/10336/25008
dc.language.isospa
dc.publisherAsociacion Colombiana de Medicina Internaspa
dc.relation.citationEndPage7
dc.relation.citationIssueNo. 1
dc.relation.citationStartPage3
dc.relation.citationTitleActa Medica Colombiana
dc.relation.citationVolumeVol. 35
dc.relation.ispartofActa Medica Colombiana, ISSN:0120-2448, Vol.35, No.1 (2010); pp. 3-7spa
dc.rights.accesRightsinfo:eu-repo/semantics/openAccess
dc.rights.accesoAbierto (Texto Completo)spa
dc.source.instnameinstname:Universidad del Rosariospa
dc.source.reponamereponame:Repositorio Institucional EdocURspa
dc.subjecttransfusión sanguíneaspa
dc.subjectevaluaciónspa
dc.subjecterror en la evaluación terapéuticaspa
dc.subject.keywordblood transfusionspa
dc.subject.keywordmonitoringspa
dc.subject.keywordtherapeutic misestimetionspa
dc.titleRompiendo un mito en el control de la hemoglobina/hematocrito postransfusiónspa
dc.title.TranslatedTitleBreaking a myth in postransfusion control of hemoglobin/hematocriteng
dc.typearticleeng
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion
dc.type.spaArtículospa
Archivos
Bloque original
Mostrando1 - 1 de 1
Cargando...
Miniatura
Nombre:
1576-Texto-del-articulo-6309-1-10-20191129.pdf
Tamaño:
253.27 KB
Formato:
Adobe Portable Document Format
Descripción:
Colecciones