Ítem
Acceso Abierto
Rompiendo un mito en el control de la hemoglobina/hematocrito postransfusión
dc.creator | Pardo Oviedo, Juan Mauricio | |
dc.creator | Panqueva Martínez, Uriel | spa |
dc.creator | Espinosa Aranzales, Ángela Fernanda | |
dc.date.accessioned | 2020-06-11T13:22:04Z | |
dc.date.available | 2020-06-11T13:22:04Z | |
dc.date.created | 2010 | spa |
dc.description | Habitualmente se ha solicitado la hemoglobina/hematocrito después de las seis horas como parámetro para evaluar el resultado terapéutico de la transfusión sin que exista evidencia clara para hacerlo. Objetivo: determinar la concordancia de los niveles de hemoglobina/hematocrito en los primeros 15 minutos de terminada la transfusión comparado con la toma de éstos a las seis horas en pacientes con anemia crónica sin sangrado activo, hemólisis o hiperesplenismo. Materiales y métodos: se realizó un estudio, observacional, analítico de concordancia que analizó la consistencia entre dos mediciones de hemoglobina/hematocrito tomada dentro de los primeros 15 minutos de terminada la transfusión y seis horas después en 41 pacientes con anemia de origen médico, sin sangrado activo. Resultados: se encontró concordancia significativa alta entre la hemoglobina a los 15 minutos y seis horas después de la transfusión (p<0.0001) con un coeficiente de correlación intraclase de 0.8793 (IC 95: 0.7817, 0.9349); igualmente se encontró concordancia significativa alta entre el hematocrito a los 15 minutos y a las seis horas después de la transfusión (p<0.0001) con un coeficiente de correlación intraclase de 0.8456 (IC 95%: 0.7301, 0.9144). Conclusiones y discusión: aunque es una práctica habitual la toma de hemoglobina-hematocrito seis horas después de la transfusión, sin evidencia en la literatura que lo respalde, este estudio encontró que existe concordancia alta, significativa entre la toma de la hemoglobina/hematocrito 15 minutos y seis horas después de terminada la transfusión en pacientes con anemia de origen médico, lo que permite una toma inmediata, ahorrando tiempo en la decisión clínica (Acta Med Colomb 2010; 35: 2-7). | spa |
dc.description.abstract | Measurement of hemoglobin/hematocrit is usually carried out 6 hours after transfusion, as a parameter allowing the assessment of therapeutic result. However, there is no clear evidence to support this practice. Objective: to determine the concordance of the levels of hemoglobin/hematocrit 15 minutes after termination of transfusion, with regard to those measured 6 hours after the procedure, in patients with chronic anemia and without active bleeding, hemolysis, or hypersplenism. Materials and methods: an observational, analytic, concordance study was carried out in order to analyze the concordance between 2 measurements of hemoglobin/hematocrit: 15 minutes after transfusion and 6 hours after transfusion. This was done in 41 diagnosed with anemia of medical origin, without active bleeding. Results: a highly significant concordance was found between hemoglobin at 15 minutes and 6 hours after transfusion (p<0.0001), with an intraclass correlation coefficient of 0.8793 (IC 95: 0.7817, 0.9349); highly significant concordance was also found between hematocrit at 15 minutes and 6 hours after transfusion (p<0.0001), with an intraclass correlation coefficient of 0.8456 (IC 95%: 0.7301, 0.9144). Conclusions and discussion: although it is common practice to determine hemoglobin/hematocrit 6 hours after transfusion (without supporting evidence reported in the literature), this study found a high, significant correlation between measurements carried out at 15 minutes and 6 hours after transfusion in patients with anemia of medical origin. Immediate measurement saves time in clinical decisions (Acta Med Colombiana 2010; 35: 2-7). | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.issn | 0120-2448 | |
dc.identifier.uri | https://repository.urosario.edu.co/handle/10336/25008 | |
dc.language.iso | spa | |
dc.publisher | Asociacion Colombiana de Medicina Interna | spa |
dc.relation.citationEndPage | 7 | |
dc.relation.citationIssue | No. 1 | |
dc.relation.citationStartPage | 3 | |
dc.relation.citationTitle | Acta Medica Colombiana | |
dc.relation.citationVolume | Vol. 35 | |
dc.relation.ispartof | Acta Medica Colombiana, ISSN:0120-2448, Vol.35, No.1 (2010); pp. 3-7 | spa |
dc.rights.accesRights | info:eu-repo/semantics/openAccess | |
dc.rights.acceso | Abierto (Texto Completo) | spa |
dc.source.instname | instname:Universidad del Rosario | spa |
dc.source.reponame | reponame:Repositorio Institucional EdocUR | spa |
dc.subject | transfusión sanguínea | spa |
dc.subject | evaluación | spa |
dc.subject | error en la evaluación terapéutica | spa |
dc.subject.keyword | blood transfusion | spa |
dc.subject.keyword | monitoring | spa |
dc.subject.keyword | therapeutic misestimetion | spa |
dc.title | Rompiendo un mito en el control de la hemoglobina/hematocrito postransfusión | spa |
dc.title.TranslatedTitle | Breaking a myth in postransfusion control of hemoglobin/hematocrit | eng |
dc.type | article | eng |
dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | |
dc.type.spa | Artículo | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- 1576-Texto-del-articulo-6309-1-10-20191129.pdf
- Tamaño:
- 253.27 KB
- Formato:
- Adobe Portable Document Format
- Descripción: