Ítem
Acceso Abierto

Capacidad aeróbica de bomberos aeronáuticos

dc.creatorAvellaneda Pinzón, Salin Eduardospa
dc.creatorUrbina Bonilla, Adriana del Pilarspa
dc.date.accessioned2020-06-11T13:22:26Z
dc.date.available2020-06-11T13:22:26Z
dc.date.created2015spa
dc.descriptionIntroducción: Los bomberos aeronáuticos atienden las emergencias en aeropuertos y sus cercanías. Su trabajo implica actividades de baja intensidad por periodos largos y, durante emergencias, actividades de alta intensidad, por lo cual es necesario que tengan buena condición física. Objetivo: Determinar la capacidad aeróbica de los bomberos aeronáuticos y sus factores determinantes. Materiales y Métodos: Estudio descriptivo transversal, en una muestra de 23 hombres bomberos aeronáuticos. Se determinó el consumo máximo de oxígeno (VO2máx) y umbral ventilatorio mediante ergo-espirometría (FitMate® Pro) durante un protocolo máximo sobre tapiz rodante. Se evaluó la composición corporal mediante adipometría. Se determinó el nivel de actividad física mediante el cuestionario internacional de actividad física IPAQ corto. Resultados y Discusión: El VO2máx fue 44,6±6,0 ml/kg/min y el umbral ventilatorio fue 40±11%. 48% de los sujetos realizaban actividad física moderada y 52% actividad física intensa. El VO2máx se correlacionó con la actividad física (r=0,72; p=0.000), y a su vez ésta con el porcentaje de grasa corporal (r= -0.46; p=0,027) e IMC (r= -0,43; p=0,039). Aunque 17 de 23 sujetos tenían IMC igual o superior a 25 kg/m², su grasa corporal se encontraba entre 12,5 y 22,8%. Conclusión: Aunque el VO2máx se encontró en buen nivel, por el tipo de tareas que los bomberos deben desarrollar durante la atención de emergencias, se sugiere mejorar el umbral anaeróbico, mediante entrenamiento de intervalos de alta intensidad. En bomberos, el IMC no parece ser adecuado para valorar riesgo cardiovascular, por lo que se sugiere utilizar el porcentaje de grasa corporal.spa
dc.description.abstractIntroduction: Aeronautical firefighters manage emergencies at airports and nearby. Their work involves low-intensity activities for long periods and, in emergencies high intensity activities that require good physical condition. Objective: To determine the aerobic capacity of aeronautical firefighters and its determinant factors. Methods: Cross sectional study in 23 male aeronautical firefighters. Maximum oxygen consumption (VO2max) and ventilatory threshold was determined by ergospirometry (FitMate® Pro) during a maximum protocol on treadmill. Body composition was assessed by adipometry. Physical activity level was determined with the international physical activity questionnaire (IPAQ) short version. Results and Discussion: VO2max was 44.6 ± 6.0 ml/kg/min and ventilatory threshold was 4± 11%. 48% of subjects were classified with moderate physical activity and 52% with vigorous. VO2max was correlated with physical activity (r = 0.72; p = 0.000), and the last with the percentage of body fat (r = -0.46; p = 0.027) and body mass index (BMI) (r = -0.43; p = 0.039). Although 17 of 23 subjects had IMC?25 kg /m², body fat was between 12.5 and 22.8%. Conclusion: Although VO2max was found in good level; because of the kind of tasks that firefighters develop during emergency attention, it is suggested to improve anaerobic threshold with high intensity intervals training. Among firefighters, BMI does not seem to be adequate to assess cardiovascular risk, and implementation of percentage of body fat is recommended.spa
dc.format.mimetypeapplication/pdf
dc.identifier.issn0121-0807
dc.identifier.urihttps://repository.urosario.edu.co/handle/10336/25126
dc.language.isospa
dc.publisherUniversidad Industrial de Santanderspa
dc.relation.citationEndPage67
dc.relation.citationIssueNo. 1
dc.relation.citationStartPage61
dc.relation.citationTitleRevista de la Universidad Industrial de Santander. Salud
dc.relation.citationVolumeVol. 47
dc.relation.ispartofRevista de la Universidad Industrial de Santander. Salud, ISSN:0121-0807, Vol.47, No.1 (2015); pp. 61-67spa
dc.rights.accesRightsinfo:eu-repo/semantics/openAccess
dc.rights.accesoAbierto (Texto Completo)spa
dc.source.instnameinstname:Universidad del Rosariospa
dc.source.reponamereponame:Repositorio Institucional EdocURspa
dc.subjectbomberosspa
dc.subjectconsumo de oxígenospa
dc.subjectumbral anaerobiospa
dc.subjectsalud laboral (Decs)spa
dc.subject.keywordfirefightersspa
dc.subject.keywordoxygen consumptionspa
dc.subject.keywordanaerobic thresholdspa
dc.subject.keywordoccupational health (Mesh)spa
dc.titleCapacidad aeróbica de bomberos aeronáuticosspa
dc.title.TranslatedTitleAerobic capacity of aeronautical firefighterseng
dc.typearticleeng
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion
dc.type.spaArtículospa
Archivos
Bloque original
Mostrando1 - 1 de 1
Cargando...
Miniatura
Nombre:
4681-Texto_del_articulo-21529-1-10-20150313.pdf
Tamaño:
1.43 MB
Formato:
Adobe Portable Document Format
Descripción:
Colecciones